SWR ProSens dust measurement

The ProSens was specially developed to carry out reliable dust measurement on clean sides after filters.

  • Output of dust concentration as absolute value in mg/m3
  • Dust measurement also in large channel diameters
  • Measurement of dust concentration at high temperatures
  • ATEX-certified (GasEx-Zone 1, DustEx-Zone 20)
  • Trend signal or absolute value

Basic principle of the ProSens is the triboelectric effect.
If the dust to be measured is constant, then the generated measuring signal is proportional to the dust concentration, even if there are dust deposits on the measuring probe. Experience shows that the measuring method provides very exact results with little required maintenance


A complete measuring system consists of these components:

  • Welded casing to serve as a sensor receptacle
  • ProSens-sensor
  • Transmitter PME 100

This unit can be supplied in a field housing with touch panel display or as a DIN rail version.
In case of a DIN rail version also a software for parameter setting will be supplied.

Technical data:

Sensor Measuring objects Particles in the gas flow
  Measurement range from 0.1 mg/m³
  Process temperature Standard: 150 °C; optional: max. 800 °C
  Pressure max. 2 bar (Optional: up to 25 bar)
  Flow speed min. 4 m/s
  Humidity 95 % rel. hum. or less
(non-condensing)
  Measuring principle Triboelectric effect
  Ambient temperature - 20... +60 °C
  Sensor rod Stainless steel; length 500 or 1,000 mm
  Housing Aluminium
  Protection type IP 66; ATEX; cat. 1/2 GD
  Electric connection Connection room DIN PG 16
  Weight Approx. 1.5 kg
     
Transmitter (DIN rail) Power supply 24 +/- 10 % V DC
  Power consumption 20 W / 24 V
  Protection type IP 40 to EN 60529
  Ambient operating temperature - 10... + 45 °C
  Dimensions 23 x 90 x118 (W x H x D)
  Weight approx. 172 g
  Connection terminals conductor cross-section 0.2 - 2.5 mm² (AWG 24-14)
  Current output signal 4 ... 20 mA, load 500 Ω
  Switch output measurement alarm Relay with switchover contact, max. 250 V AC, 1 A
  Interface ModBus RTU (RS 485)
  Data backup Flash memory
     

 

ADD FILES

Envea (SWR)

Pomiar pyłu za filtrem workowym ProSens
Czujnik pyłu za filtrem
Ciągły pomiar stężenia pyłu
Czujnik pyłu metali
Pomiar stężenia pyłu metali
Pomiar pyłu w wysokiej temperaturze
Pomiar pyłu w strefie wybuchowej
Kontrola filtra workowego
Ciągły pomiar stężenia pyłu

DUST METERS

ABOUT COMPANY   REFERENCE   OFFER   SALE OF COMPONENTS   COOPERATION   CONTACT

Projekt oraz realizacja Agencja Reklamowa aktywwwni.pl Wszystkie prawa zastrzeżone.

automatyka

Informujemy, że nie prowadzimy sprzedaży katalogowej ani internetowej. Nasze strony WWW oraz katalogi należy traktować jako informację o asortymencie, a nie jako ofertę handlowa.