Oxygen analyser (650-1250/1350C)

Insitu zirkonia analyser with ceramic probe.

  • Measurement range: 0,1%-25% O2,
  • Displayed range: 0-20,9% O2,  0-25,0% O2 available,
  • Displayed „λ”, too.
  • Accuracy in range 0-10% O2 is ±1% (0,1% O2); w zakresie 0-20,9% O2 ±2% (0,2% O2).
  • Sample temperature: 650°C-1250°C or 650°C-1250°C with ceramic probe.
  • Response time: Tmin95% = 2,5 sek.
  • 2 alarms level (min/max O2) (relay output 24V/0,1A).
  • 2 Analog outputs (galvanic isolation 1,5kV) 0-20mA or 4-20mA
  • RS-232 lub RS-485 avaliable
  • Power supply 230V, 50Hz.
  • Power consumption 40VA
  • Ambient temperature of elektronical module: 15 to +60°C.>
  • Electronical module weight (wires excluded): 1,5kg.
  • Sensor weight 500 mm long: 3 kg.
  • Probe lenght: 300 ÷ 600mm.

 